We are currently undergoing R&D phase on a cuffless blood pressure monitor, allowing constant imaging of the results (Microwave + PPG)

Project Aim

The project aims to create a method for continuous blood pressure monitoring in hypertensive patients, however, completely bypassing traditional, cumbersome testing methods such as a pumped cuff or sensing nodes placed on the subject’s body.

Measurement method

To enable continuous measurement of blood pressure using a single measuring point, we will combine the results from the PAT/ PTT method with a method using a multi-wavelength PPG sensor and a microwave sensor analysing the pulse waveform of the pulse. The device will be convenient to be worn continuously and discreetly by the patient (analogous to an ECG holter or wearables).
This system does not require the utilization of an arterial canal or catheterisation, which can only be performed on hospitalised patients. It also does not require the use of a cuff worn on the arm, commonly used to measure blood pressure at home or in the office. Cuff devices measure systolic and diastolic blood pressure by auscultation or oscillometry.

Range of application

The direction of fast and wearable medical devices connected to telemedicine systems becomes apparent in hospitalisation, telemedicine and in cases where the patient’s treatment is to take place at home.

 

In each of these cases, wireless devices that are able to perform measurement data transmission in addition to the diagnostic function are particularly desirable on the market. This is due to the fact, that many patients with cardiac conditions are advised to exercise at home, e.g. treadmill, or bicycle.

​MediSensonic Sp. z o.o. is implementing a project co-financed by European Funds entitled 'Development of an innovative method and device for continuous measurement of human blood pressure without the use of a sleeve'.
POIR.01.01.01-00-0800/20

The aim of the project is to market an innovative method and device for continuous measurement of human blood pressure without the use of a sleeve.

EU funding for the project: 8 875 633,71 PLN